Available for work in Colorado and Coast to Coast — It all starts with a simple phone call.
1-866-759-7732
Failed glass needs to be replaced.
We have made an initial evaluation and found a total of nine bays with broken glass or failed seals.
We will replace the failed glass and perform a complete wet seal of the entire system.
Replacing failed glass units.
We have made an initial evaluation and found a total of eleven bays with broken glass or failed seals.
We will replace the failed glass and perform a complete wet seal of the entire system.
Wet seal done right.
With a crew on site, it made economical sense to perform a wet seal of the system.
We follow the manufacturer’s recommended procedures and remove old sealant, clean with alcohol or other solvent and mask the joints before applying Dowsil 795 structural sealant.
Project is complete.
A wet seal done properly will provide several more years of leak free service.
Product used:
- Heat strengthened laminate Solarban® 90 glass.
- Dowsil 795 structural silicone sealant.